note: all specifications are subjec t to change without notification. scd's for these devices should be re viewed by ssdi prior to release. data sheet #: ra0100a doc solid state devices, inc. 14701 firestone blvd * la mirada, ca 90638 phone: (562) 404-7855 * fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com designer?s data sheet part number / ordering information 1 / spa612 __ __ __ screening 2 / __ = not screened tx = tx level txv = txv level s = s level recovery time __ = standard recovery voltage/family c = 400 v d = 500 v e = 600 v spa612 series 150 a / 600 v three phase bridge rectifier assembly features: ? average output current 150 amps ? high temperature operation ? anodized aluminum base ? high power density 40 w / sq in ? tx, txv & s level screening available ? standard, fast, & hyper fast versions available. contact factory. ? higher voltage versions available. contact factory. maximum ratings 3 / symbol value units peak inverse voltage SPA612C spa612d spa612e piv 400 500 600 volts average rectified output current (t c = case temperature) t c = 55 c t c = 100 c t c = 130 c i o1 i o2 i o3 150 100 60 amps peak surge current (8.3 ms pulse, half sine wave, t c = 25 c ) i fsm 1000 amps operating & storage temperature t op & t stg -65 to 150 oc maximum thermal resistance, junction to case r ? jc 0.4 oc/w notes: spa612 series 1 / for ordering information, price, and availability contact factory. 2 / screened to mil-prf-19500. 3 / unless otherwise specified, all maximum ratings/electrical characteristics @25oc.
note: all specifications are subjec t to change without notification. scd's for these devices should be re viewed by ssdi prior to release. data sheet #: ra0100a doc solid state devices, inc. 14701 firestone blvd * la mirada, ca 90638 phone: (562) 404-4474 * fax: (562) 404-1773 ssdi@ssdi-power.com * www.ssdi-power.com spa612 series electrical characteristic 3 / symbol min typ max units maximum forward voltage per leg (t a = 25c, pulsed) i f = 150 a i f = 100 a i f = 60 a v f1 v f2 v f2 - - - 1.08 1.02 0.96 1.50 1.30 1.05 volts maximum forward voltage per leg (t a = 125c, pulsed) i f = 150 a i f = 100 a i f = 60 a v f1 v f2 v f2 - - - 0.98 0.93 0.85 1.20 1.10 0.95 volts reverse leakage current (rated piv, t a = 25oc) i r1 - 5 50 ? a reverse leakage current (rated piv,) t a = 100oc t a = 125oc i r2 i r3 - - 50 125 500 1000 ? a isolation resistance 1500v r iso 100 --- --- m ? reverse recovery time (i f = 500 ma, i r = 1 a, i rr = 250 ma t a = 25oc (measured on discrete rectifiers prior to assembly) trr ?? 2.5 5.0 us spa612 package outline:
|