p o w e r t r a n s f o r m e r p c m o u n t : split pack web: www.triadmagnetics.com phone 951 - 277 - 0757 fax 951 - 277 - 2757 460 harley knox blvd. perris, california 92571 publish date: december 4, 2013 fs 12 - 500 description: the fs 12 - 500 is a dual primary and dual secondary, split bobbin design which operates with either a parallel input of 115v or a series input of 230v. the output voltage will be either 12.6 v with a center - tap under a 0.5 a load with t he secondaries wired in series, or 6.3 v under a 1.0 a load with the secondaries wired in parallel. the split bobbin design eliminates the need for costly electrostatic shielding. electrical specifications (@25c) 1. maximum power: 6.0 va 2. primary: series: 230v ; parallel: 115v 3. secondary: series: 12.6 v ct@ 0.5 a; parallel: 6.3 v @ 1.0 a 4. voltage regulation: 25% typ @ full load to no load 5. temperature rise: 25c typ 6. hipot tested 100% at 2500 vrms construction: three flange bobbin const ruction with prim aries and secondaries wound side by sid e for low capacitive coupling. agency file: ul: file e53148, ul 5085 - 2 ( 506 ) , class b general purpose transformer, c ul: file e53148, ul 5085 - 2 ( 506 ) , class b general purpose transformer, canadian use (csa 22.2, no.6 6.2 - 06) this model is also available in class 2, ul 5 085 - 3 (1585) version as fs12 - 500 - c2 dimensions: units in inches. h w l a b c d e f 1.312 1.312 1.625 0.250 0. 3 50 1.2 8 0 0.041 0.020 0.234 weight: 0.44 lbs schematic : rohs compliance: as of manufacturing date february 2005, all standard products meet the requirements of 2011/65/eu, known as th e rohs initiative. as of april 7, 2008, ul standards 506 and 1585 will be migrated to ul 5085 - 2 and 5085 - 3, respectively. * upon printin g, this document is considered uncontrolled . please contact triad magnetics website for the most current version. board layout 1 2 3 4 8 7 6 5 115/230v 50/60hz 1 2 3 4 115/230v 50/60hz parallel 1 2 3 4 115/230v 50/60hz series 1 2 3 4 l h w e a b a c 0.06" diameter hole d f 1 5 8 4
|