Part Number Hot Search : 
092315 SC120 106M16 XC61C F2807 DS152 001591 STD90
Product Description
Full Text Search
 

To Download TFS675 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  filename: tfs 675.doc version 1.3 29.07.2004 vi telefilter filter specification tfs 675 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation. measurement condition ambient temperature: 23 c input power level: 0 dbm terminating impedance: input: 50 output: 50 characteristics remark: the maximum attenuation in the pass band is defined as the insertion loss a e . the nominal frequency f n is fixed at 675 mhz without any tolerance or limit. the values of abs olute attenuation a abs are guaranteed for the whole operating temperature range. the frequency shift of the filter in the operating temperature range is included in the production tolerance scheme. d a t a typ. value tolerance / limit insertion loss a e 2 db max. 3 db nominal frequency f n - 675 mhz passband pass band ripple 0,7 db f n 15 mhz max. 1 db bandwidth bw 3 db min. 40 mhz absolute attenuation a abs 1 mhz ... 575 mhz 60 db min. 30 db 775 mhz ... 1350 mhz 48 db min. 30 db 1350 mhz ... 1500 mhz 54 db min. 50 db group delay ripple within pb 7 ns max. 10 ns input power level max. 10 dbm vswr within pb 1,4:1 max. 1,6:1 operating temperature range otr - - 40 c ... + 85c storage temperature range - - 40 c ... + 85c temperature coefficient of frequency tc f * -72 ppm/k - *) ? f(hz) = tc f (ppm/k) x (t-t 0 ) x f to (mhz). generated: checked / approved:
filename: tfs 675.doc version 1.3 29.07.2004 vi telefilter filter specification tfs 675 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation. filter characteristic construction and pin connection (all dimensions in mm) sq 3 , 8 1 -0,10 +0,20 1 3 7 5 1,2 max. 0,6 1,78 0,1 1,78 2,54 1 2 0 13 5 7 date code 50 ? test circuit 675 s31 1 ground 2 input 3 ground 4 ground 5 ground 6 output 7 ground 8 ground date code: year + week s 2004 t 2005 u 2006 ... 475 515 555 595 635 675 715 755 795 835 875 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 frequency in mhz magnitude in db 646 651.8 657.6 663.4 669.2 675 680.8 686.6 692.4 698.2 704 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 frequency in mhz magnitude in db 646 651.8 657.6 663.4 669.2 675 680.8 686.6 692.4 698.2 704 0 3 6 9 frequency in mhz vswr l1 l2 2 6 1, 3, 4, 5, 7, 8
filename: tfs 675.doc version 1.3 29.07.2004 vi telefilter filter specification tfs 675 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation. stability characteristics after the following tests the filter shall meet the whole specification: 1. shock: 500g, 18 ms, half sine wave, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respecti vely, 1 octave per min, 10 cycles per plan, 3 plans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 10 cycles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow): reflow possible: twice max.; for temperature conditions refer to the attac hed "air reflow temperature conditions" on page 4; packing tape & reel: iec 286 ? 3, with exeption of value for n and minimum bending radius; tape type ii, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: 3000 reel of empty components at start: min. 300 mm reel of empty components at start including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao pull off direc tion pin m a rke r t yp da te c od e ko t a c n w 1 w 2 the minimum bending radius is 45 mm. tape (all dimensions in mm) w : 12,00 0,3 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,1 f : 5,50 0,05 g(min) : 0,75 p2 : 2,00 0,05 p1 : 8,00 0,1 d1(min) : 1,50 a o : 4,30 0,1 bo : 4,30 0,1 ct : 9,5 0,1 reel (all dimensions in mm) a : 330 w1 : 12,4 +2/-0 w2(max) : 18,4 n(min) : 50 c : 13,0 +0,5/-0,2
filename: tfs 675.doc version 1.3 29.07.2004 vi telefilter filter specification tfs 675 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation. air reflow temperature conditions 1st and 2nd air reflow profile name: pre-heating periods main-heat ing periods peak temperature temperature: 150 c - 170 c over 200 c 255 c 5 c time: 60 sec. - 90 sec. 20 sec. - 25 sec. chip-mount air reflow profile time / sec. temperature / c 0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 20 40 60 80 100 120 140 160 180 200 220 240 table for temperature vs. time during the air reflow process tolerance of temperatures: 5 c time / sec. temperature / c time / sec. temperature / c 0 23 140 160 10 34 150 161 20 46 160 164 30 60 170 170 40 80 180 180 50 103 190 205 60 121 195 230 70 134 200 255 80 143 205 230 90 150 210 205 100 154 215 180 110 156 220 165 120 158 230 140 130 159 240 120
filename: tfs 675.doc version 1.3 29.07.2004 vi telefilter filter specification tfs 675 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.com vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein without notice. no liab ility is assumed as a result of their use or application. no rights under any patent accompany the sale of any such product(s) or infor mation. history : version reason of changes name date 1.0 - generation of specification according to customer requirements. roizengaft 27.02.2004 1.1 - change of vswr. springfeldt 25.03.2004 1.2 - change of group delay ripple within pb springfeldt 07.04.2004 1.3 - add typical values springfeldt 29.07.2004 - add filter characteristic


▲Up To Search▲   

 
Price & Availability of TFS675

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X