  specifications features min. the fcx? a iii pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20ma signal. the transmitter utilizes the unique micromachined capaci- tive silicon sensor with state-of-the-art microprocessor tech- nology to provide exceptional performance and functionality. 1. high accuracy ?.1% 0.1% accuracy is a standard feature. fuji?s micro-capaci- tance silicon sensor assures this accuracy for all elevated or suppressed calibration ranges without additional adjust- ment. 2. minimum environmental in uence the ?advance floating cell? design which protects the pressure sensor against changes in temperature, and overpressure substantially reduces total measurement error in actual ? eld applications. 3. fuji/hart bilingual communications protocol fcx? a iii series transmitter offers bilingual communica- tions to speak both fuji proprietary protocol and hart ? . any hart ? compatible devices can communicate with fcx? a iii . 4. application exibility various options that render the fcx? a iii suitable for almost any process applications include: ? full range of hazardous area approvals ? built-in rfi ? lter and lightning arrester ? 5-digit lcd meter with engineering unit 5. burnout current exibility (under scale: 3.2 to 4.0ma, over scale: 20.0 to 22.5ma) burnout signal level is adjustable using model fxw hand held communicator (hhc) to comply with namur ne43. 6. dry calibration without reference pressure thanks to the best combination of unique construction of mechanical parts (sensor unit) and high performance electronics circuit (electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration. functional speci cations service: liquid, gas, or vapour span, range and overrange limit: overrange limit [mpa] {bar} type fkp ? 01 fkp ? 02 fkp ? 03 fkp ? 04 ? lower range limit (vacuum limit) is; silicone ? ll sensor: see fig. 1 fluorinated ? ll sensor: 66kpa abs (500mmhg abs) at below 60c output signal: 4 to 20ma dc with digital signal super- imposed on the 4 to 20ma signal. span limit [kpa] {bar} range limit [kpa] {bar} max. ?100 to + 130 {?1 to +1.3} ?100 to + 500 {?1 to +5} ?100 to + 3000 {?1 to +30} ?100 to +10000 {?1 to + 100} 8.125 {0.08125} 31.25 {0.3125} 187.5 {1.875} 625 {6.25} 130 {1.3} 500 {5} 3000 {30} 10000 {100} 1 {10} 1. 5 {15} 9 {90} 15 {150} pressure transmitter (direct mount type) data sheet fkp ... 5 EDSX5-98G aug. 10, 2011 date
2 fkp ... 5 power supply: transmitter operates on 10.5v to 45v dc at transmitter terminals. 10.5v to 32v dc for the units with optional arrester. load limitations: see ? gure below note: for communication with hhc (1) (model: fxw), min. of 250 ? required. hazardous locations: see table3 zero/span adjustment : zero and span are adjustable from the hhc (1) . zero and span are also adjustable externally from the adjustment screw. damping: adjustable from hhc or local con? gurator unit with lcd display. the time constant is adjustable between 0.06 to 32 seconds. zero elevation/suppression: zero can be elevated or suppressed within the speci? ed range limit of each sensor model. normal/reverse action: selectable from hhc (1) . indication: analog indicator or 5-digit lcd meter, as speci? ed. burnout direction: selectable from hhc (1) if self-diagnostic detect transmitter fail- ure, the analog signal will be driven to ei- ther ?output hold?, ?output overscale? or ?output underscale? modes. ?output hold?: output signal is hold as the value just before failure happens. ?output overscale?: adjustable within the range 20.0ma to 22.5ma from hhc (1) ?output underscale?: adjustable within the range 3.2ma to 4.0ma from hhc 3.2 4 20 22.5 [ma] over scale burnout probable over range probable under range normal operating range under scale burnout output limits conforming to namur ne43 by order. loop-check output: transmitter can be con? gured to provide constant signal 3.2ma through 22.5ma by hhc. temperature limit: ambient: ? 40 to +85c (?20 to +80c for lcd indicator) (? 40 to +60c for arrester option) (?10 to +60c for fluorinated oil fill transmitter) for explosionproof units (? ameproof or intrinsic safety), ambient temperature must be within the limits speci? ed by each standard. process: ? 40 to +100c for silicone ? ll sensor ?20 to +80c for ? uorinated oil ? ll sen- sor storage: ?40 to +90c humidity limit: 0 to 100% rh communication: with hhc (1) (model fxw, consult data sheet no. eds8-47), following items can be remotely displayed or con? gured. note: hhc?s version must be higher than 7.0 (or fxw 1? 4), for fcx - a iii . local con gurator with lcd display (option): local con? gurator with 3 push button and lcd display can support following items. items by communication with fxw by local con? gurator (with 3 push button) display set display set tag no. vvvv model no. vvvv serial no. & software version v ? v ? engineering unit vvvv range limit v ? v ? measuring range vvvv damping vvvv output mode v ? v ? burnout direction vvvv calibration vvvv output adjust ? v ? v data v ? v ? self diagnoses v ? v ? printer (in case of fxw with printer option) v ??? external switch lock vvvv transmitter display vvvv linearize vv ?? rerange vvvv saturate current vvvv write protect vvvv history ? calibration history ? ambient temperature history v v v ? v v v ? emc conformity: en61326-1: 2006 2000 [ ] 1500 1000 load resistance 500 250 0 1474 577 operating area 24v 45v 10 16.35 50 e[ v ] 10.5v power voltage (dc) r= e-10.5 (imax+0.9)x10 -3 (note) (1) hhc: hand held communicator
3 physical speci cations electrical connections: g1/2, 1/2-14 npt, pg13.5, or m201.5 conduit, as speci? ed. process connections: 1/2-14npt, rc1/2, rc1/4 or 1/4-18npt, as speci? ed. process-wetted parts material: performance speci cations accuracy rating: (including linearity, hysteresis, and re- peatability) for spans greater than 1/10 of url: 0.1% of span for spans below 1/10 of url : (0.05 + 0.05 ) % of span stability: 0.2% of upper range limit (url) for 10 years (in case of 6th digit code ?2?, ?3?, ?4?) temperature effect: effects per 55c change between the limits of ? 40c and +85c zero shift : (0.4 + 0.1 )%/28c total effect: (0.475 + 0.1 )%/28c overrange effect: zero shift, 0.3% of url for any overrange to maximum limit supply voltage effect: less than 0.05% of calibrated span per 10v update rate: 60 msec step response: time constant: 0.08s (at 23c) dead time: about 0.12s (without electrical damping) mounting position effect: zero shift, less than 0.1kpa {1mbar} for a 10 tilt in any plane. no effect on span. this error can be cor- rected by adjusting zero. (double the effect for ? uorinated ? ll sen- sors) dielectric strength: 500v ac, 50/60hz 1 min., between circuit and earth insulation resistance: more than 100m ? at 500v dc internal resistance for external eld indicator: 12 ? or less. v 316 stainless steel m a t e r i a l c o d e ( 7 t h d i g i t i n c o d e symbols) process cover diaphragm wetted sensor body 316 stainless steel 316l stainless steel non-wetted parts material: electronics housing: low copper die-cast aluminum alloy (standard), finished with polyester coating. fill ? uid: silicone oil (standard) or ? uori- nated oil (dai? oil) mounting bracket: 304 stainless steel environmental protection: iec ip67 and nema 6/6p mounting: on 60.5mm (jis 50a or 2b) pipe using mounting bracket, direct wall mounting, or direct process mounting. mass{weight}: transmitter approximately 2.2kg without options. add; 0.5kg for mounting bracket 0.1 x url span url span url span
4 fkp ... 5 optional features indicator: a plug-in turnable analog indicator (2.5% accuracy) an optional 5digits lcd meter with engi- neering unit is also available. local con gurator with lcd display: an optional 5 digits lcd meter with 3 push buttons can support items as using communication with fxw. arrester: a built-in arrester protects the electronics from lightning surges. lightning surge immunity: 4kv (1.2 x 50 s) oxygen service: special cleaning procedures are followed throughout the process to maintain all process wetted parts oil-free. the ? ll ? uid is ? uorinated oil. degreasing: process-wetted parts are cleaned, but the ? ll ? uid is standard silicone oil. not for use for oxygen or chlorine measurement. nace speci cation: metallic materials for all pressure bound- ary parts comply with nace mr-01-75. optional tag plate: an extra stainless steel tag with customer tag data is wired to the transmitter. hand-held communicator: (model fxw, refer to data sheet no. eds8-47) fig. 1 relation between process temperature and operating pressure ?40 60 100 none-operating area 2.7 (20) 4 (30) 20 operating pressure process temperature [c ] (150) 101 (760) [kpa abs] (mmhg abs) silicone oil (code:y,g,n) operating area accessories
5 code symbols process connection 1 /2 -14npt 1 /2 -14npt 1 /2 -14npt 1 /2 -14npt conduit connection g 1 /2 1 /2 -14npt pg13.5 m20 1. 5 case type t type t type t type t type note1: (*1) available for 4th digit code "5". note3: (*3) available for 4th digit code "6", "8". note4: (*4) available for 4th digit code "6". note5: (*5) customer tag number can be engraved on standard stainless steel name plate. if extra tag plate is required select "yes". note6: (*6) if other option is not necessary, 21st digit code is blank. in case of 21st digit code is blank, instruction manua l attached. (*5) a b d e f h l p q s 1 2 4 5 a c g d h v x k p m r t e j f s u y g a n y b a c y a b c l fkp kpa {bar} 8.125 130 {0.08125 1.3} 31.25 500 {0.3125 5} 187.5 3000 {1.875 30} 625 1 0000 {6.25 100} process cover diaphragm wetted cell body 316 stainless steel 316l stainless steel 316 stainless steel indicator arrester none none analog, 0 to 100% linear scale none analog, custom scale none none yes analog, 0 to 100% linear scale yes analog, custom scale yes digital, 0 to 100% linear scale none digital, custom scale none digital, 0 to 100% linear scale yes digital, custom scale yes digital, 0 to 100% linear scale (local configurator unit with lcd displey) none digital, custom scale (local configurator unit with lcd displey) none digital, 0 to 100% linear scale (local configurator unit with lcd displey) yes digital, custom scale (local configurator unit with lcd displey) yes none (for ordinary locations) tiis, flameproof (cable gland seal) (*1) tiis, intrinsic safety fm, flameproof (or explosionproof) (*4) fm, intrinsic safety and nonincentive fm combined of flameproof and intrinsic safety (*4) atex flameproof (*3) atex intrinsic safety atex type n atex combined of flameproof and intrinsic safety (*3) iecex scheme, flameproof (*3) iecex scheme, intrinsic safety csa, flameproof (or explosionproof) (*4) csa, intrinsic safety and nonincentive nepsi, flameproof (or exprosionproof) nepsi, intrinsic safety nepsi, combined of flameproof and intrinsic safety none yes (stainless steel) stainless tag none yes treatment filled liquid none (standard) silicon oil degreasing silicon oil oxygen service fluorinated oil nace specification silicon oil none (1/2 -14npt) rc1/4 rc1/2 1/4-18npt (*6) instruction manual unattached 1 2 3 4 v 4567 123 f0 0 5 kp 89 10 11 12 13 14 15 21 note note 1 note 4 note 4 note 3 note 3 note 3 note 4 note 5 note 6 digit 4 6 7 9 10 11 12 13 15 21 description digit no. of code 5 6 7 8
6 fkp ... 5 outline diagram (unit:mm)  - ,    /15 % 4&&5"#-&   ' & uiejhjupguif dpeftzncpmt  (   %&' $poevjudpoo 5"#-& 5"#-&  /15    1h    .   %&5"*-% %&5"*-" %&5"*-# 4&&5"#-& .5(#-"$,&5     (  "13&44$0// %"%"15&3 015*0/
4&&5"#-&  #$0/%6*5$0//  */$"4&0'5)%*(*5$0%&   */$"4&0'5)%*(*5$0%& ;&30"%+4$3&8   6#0-5.  4&&5"#-& )0-&4%*"   .5(1*1&+*4" #
 "%"15&3 $0// - ( ) + , 3d     /15 3d     + ) &"35)5&3.*/"- ;&30 
8*5)%*(*5"-*/% 
 8*5)"/"-0(*/%  /05&
*/$"4&0'5)$0%& ?$? $"#-&*446*5#-& ( %&5"*-l$z    ( 015*0/1"354'03'-".&1300'0'5**4 +"1"/
uiejhjudpef$ $bcmfhmboeuzqf
 /05&
$"#-&(-"/%    $$0/%6*5$0// 445"(1-"5& $0//&$5*0/%*"(3". $, $,  
7 atex ex ii 2 gd ex d iic t6 ip66/67 t85c tamb = ?40c to +65c ex d iic t5 ip66/67 t100c tamb = ?40c to +85c factory mutual class i div.1 groups b, c, d t6 type 4x class ii iii div.1 groups e, f, g t6 type 4x tamb max = +60c authorities flameproof iecex scheme ex d iic t5 ip66/67 tamb = ?40c to +85c ex d iic t6 ip66/67 tamb = ?40c to +65c csa class i div.1 groups c, d class ii div.1 groups e, f, g class iii div.1 note) seal not required enclosure is allowed. tiis ex do iib+h 2 t4 tamb max = +60c maximum process temp. = +120c nepsi ex d iib+h 2 t6 tamb = ?40c to +60c atex ex ii 1 g ex ia iic t5 tamb = C40c to +50c ex ia iic t4 tamb = C40c to +70c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) factory mutual class i ii iii div.1 groups a, b, c, d, e, f, g t4 entity type 4x entity parameters: vmax=28v, imax=94.3ma, pi=0.66w, ci=35.98nf, li=0.694mh authorities intrinsic safety iecex scheme ex ia iic t4 tamb = C40c to +70c ex ia iic t5 tamb = C40c to +50c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=26nf (without arrester), li=0.6mh (without analog indicator), ci=36nf (with arrester), li=0.7mh (with analog indicator) csa class i div.1 groups a, b, c, d class ii div.1 groups e, f, g class iii div.1 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, imax=94.3ma, ci=25nf (without arrester), ci=36nf (with arrester), li=0.6mh (without analog meter), li=0.7mh (with analog meter) model code 9th digit 13th digit tamb a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c ? a ?10c to +60c tiis ex ia iic t4 tamb max = +60c entity parameters: ui=28v, ii=94.3ma, pi=0.66w, ci=38.4nf, li=0.694mh nepsi ex ia iic t4 ex d iib+h 2 t6 / ex ia iic t4 entity parameters: ui=42.4v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh model code 9th digit 13th digit a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c ? a ?10c to +60c tamb atex ex ii 3 gd eex nl iic t5 tamb = ?40c to +50c eex nl iic t4 tamb = ?40c to +70c specific parameters: model without arrester: ui=42.4v, ii=113ma, pi=1w, ci=25.18nf, li=0.694mh model with arrester: ui=32v, ii=113ma, pi=1w, ci=35.98nf, li=0.694mh eex nal iic t5 tamb = ?40c to +50c eex nal iic t4 tamb = ?40c to +70c specific parameters: model without arrester: umax=42.4v, imax=113ma, pmax=1w, model with arrester: umax=32v, imax=113ma, pmax=1w factory mutual (pending) class i ii iii div.2 groups a, b, c, d, f, g t4 entity type 4x authorities type n nonincendive csa class i div.2 groups a, b, c, d class ii div.2 groups e, f, g class iii div.2 temp code t5 tamb max = +50c temp code t4 tamb max = +70c entity parameters: vmax=28v, ci=25.18nf (without arrester), ci=35.98nf (with arrester), li=0.694mh model code 9th digit 13th digit tamb a,b,d y,g,n ?40c to +85c l,p,1,2 y,g,n ?20c to +80c q,s,4,5 y,g,n ?20c to +60c e,f,h y,g,n ?40c to +60c ? a ?10c to +60c table 3
fkp ... 5 printed in japan caution on safety *before using this product, be sure to read its instruction manual in advance. international sales div sales group gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fujielectric.com phone: 81-3-5435-7280, 7281 fax: 81-3-5435-7425 http://www.fjielectric.com/products/instruments/ information in this catalog is subject to change without notice.


▲Up To Search▲   

 
Price & Availability of EDSX5-98G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X