double balanced mi x er octave band model MO6XXN rf 6.0 to 12.5 ghz lo (ghz) 5.0-15.0 5.0-15.0 5.0-15.0 5.0-15.0 5.0-15.0 5.0-15.0 5.0-15.0 rf (ghz) 6.0-12.5 6.0-12.5 6.0-12.5 6.0-12.5 6.0-12.5 6.0-12.5 if (mhz) d c -1000 d c -2500 d c -2500 d c -2500 d c -2500 min 25 db 25 db typical 4 .5 db 5.5 db 37 db 41 db 22 db +1 dbm +4 dbm +8 dbm +12 dbm +11 dbm +14 dbm +18 dbm +22 dbm +7 dbm +10 dbm +14 dbm +19 dbm max 6.5 db 7 .5 db mo63 mo64 mo66 mo67 mo63 mo64 mo66 mo67 mo63 mo64 mo66 mo67 conditions electrical specifications (1) : parameter ssb conversion loss: (2) (3) isolation l o to rf: lo to if: rf to if: input 1-db compression point: input third order intercept point: lo power: (4) drop-in module or w ith sma(f) connectors m = module p = with connectors lo power 3 = +7 dbm 4 = +10 dbm 6 = +14 dbm 7 = +19 dbm notes: 1. specifications are guaranteed when tested as a downconverter in a 50 ohm system from -55 ? c to +100 ? c with the nominal lo powe r . specifications indicated as typical are not guaranteed. 2. noise figure is typically within 0.5 db of conversion loss for if frequencies greater than 10 mhz. 3. conversion loss typically degrades less than 0.5 db at +100 ? c and improves less than 0.5 db at -55 ? c. 4. usable lo drives are up to 2 db below and 3 db above nominal. t ypica l p er f o r manc e a t 2 5 ? c all dimensions are in inches and [mm]. outline: n MO6XXN spectru m model MO6XXN specifications spectrum microwave 2144 franklin drive n.e. palm ba y , fl 32905 ph (888) 553-7531 fax (888) 553-753 2 spectrum microwave (europe) 2707 black lake place philadelphia, pa 19154 ph (215) 464-4000 fax (215) 464-4001 ww w .spectrummicrowave.co m
|