Part Number Hot Search : 
SB1650 PESD5V0L P80NF06 SST112 OIP101 BD544B MC78L12A A128A
Product Description
Full Text Search
 

To Download TFS365B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Measurement condition
Ambient temperature TA: Input power level: Terminating impedances at fc *):
Filter specification
TFS 365B
1/5
23 C 0 dBm input: 590 // -6,6 pF output: 260 // -5,5 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 365B is the minimum of the pass band attenuation amin. The minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 0,8 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 365 MHz without any tolerance. The given values for both the relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data Insertion loss
(reference level)
typ. value ae fN fc PB 9 dB
tolerance / limit max. 14,5 dB
Nominal frequency Centre frequency at ambient temperature Pass band Amplitude ripple within PB In band ripple
(in any 112,5 kHz increment within the PB)
365,025 MHz 0,3 fN max. max.
365
MHz -
dB
0,5 MHz 0,8 dB 0,5 dB p-p
0,15 dB arel ......... fN fN fN fN fN + 0,5 1,5 1,5 3,2 3 1,5 MHz MHz MHz MHz MHz GHz 0,3 40 44 43 55 54 1,6 90 1 22 C 2 -0,04 ppm/K dB dB dB dB dB dB s ns deg p-p
Relative attenuation fN fN fN fN + fN + 1,2 3,0 1,5 0,3 3,2 MHz MHz MHz MHz MHz
max. min. min. min. min. min. max.
0,8 dB 35 40 40 50 50 2 dB dB dB dB dB s ns deg p-p dBm**) C C
......... ......... ......... ......... .........
Group delay at fN Group delay ripple in PB
(in any 112,5 kHz increment within the PB)
max. 120 max. max. 5 20
Phase linearity in PB
(in any 112,5 kHz increment within the PB)
Input power level Operating temperature range Storage temperature range Turnover temperature To Temperature coefficient of frequency TCf***
- 40 C ... + 70 - 40 C ... + 100 -
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team. **) This power level is only allowed for short term operation (10% of the life time), the max. input power for continuous operation is max.15dBm only ***) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
generated: checked / approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter characteristic
0 -10 -20 -30
Filter specification
TFS 365B
2/5
0 -1 -2 -3 B d n i e d u t i n g a m -4 -5 -6 -7 -8 -9
2.42 2.33 2.24 2.15 2.06 s 1.97i n y a 1.88l e d 1.79 1.7 1.61
B d n i e d u t i n g a m
-40 -50 -60 -70 -80 -90 -100 352.9 355.3 357.7 360.1 362.5 364.9 367.3 369.7 372.1 374.5 376.9 frequency in MHz
1.52 -10 363.9 364.1 364.3 364.5 364.7 364.9 365.1 365.3 365.5 365.7 365.9 frequency in MHz
Construction and pin connection
(All dimensions in mm)
6,50 +/-0,20
TFS 365B S35
15,32 +/-0,20
1,80 +/-0,20
1 2 3 4 5 6 7 8 9 10
Input RF Return Ground Ground Ground Output Output Ground Ground Ground Input
7,62 +/-0,20 1,91
2,21
Date code: S T U ... Year + week 2004 2005 2006
50 Test circuit
10 1 5 6
L6
L5
0,10
1,02
L4
2, 3, 4, 7, 8, 9
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Stability Characteristics
Filter specification
TFS 365B
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions, please refer to the attached "Air reflow temperature conditions" on page 4;
Packing
Tape & Reel: IEC 286 - 3, with exeption of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters peer reel: reel of empty components at start: reel of empty components at start including leader: trailer: 2000 min. 300 mm min. 500 mm min. 300 mm
Pull Off Direction
Tape (all dimensions in mm) W : 24,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 11,50 0,1 G(min) : 0,60 P2 : 2,00 0,1 P1 : 12,00 0,1 D1(min) : 1,50 Ao : 7,10 0,1 Bo : 15,90 0,1 Ct : 21,5 0,1
Date Code P1 Po P2
t
Do
G Ct Bo F
Ko Typ PIN Marker D1 Ao
W2 A C N W1
E G W
Reel (all dimensions in mm) A : 330 W1 : 24,4 +2/-0 W2(max) : 30,4 N(min) : 60 C : 13,0 +0,5/-0,2
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 365B
4/5
1st and 2nd air reflow profile
Name: Temperature: Time:
pre-heating periods 150 C - 170 C 60 sec. - 90 sec.
main-heating periods over 200 C 20 sec. - 25 sec.
peak temperature 255 C 5 C
Air reflow profile
260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240
Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 365b.doc
Version 1.4
24.08.2004
VI TELEFILTER
Filter specification
TFS 365B
5/5
History
Version 1.0 1.1 1.2 1.3 Reason of Changes Generate development specification Change of relative attenuation from 39 dB to 35 dB Change of relative attenuation in between fc + 3MHz....fc + 3,2 MHz terminating impedance (preliminary values) and typical vales added triple transit limits removed 1.4 turn over temperature, temperature coefficient and filter characteristic added Pfeiffer 24.08.2004 Name Roizengaft Dr. Wall Pfeiffer Pfeiffer Date 22.12.2003 12.01.2004 16.02.2004 20.02.2004
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS365B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X