Part Number Hot Search : 
TSOP1 SA16B3 4700T 74S133DC MAX1822 1H100 TIP30 LT6200
Product Description
Full Text Search
 

To Download TFS900 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Filename: tfs 900.doc
Version 1.1
18.05.2006
VI TELEFILTER
Measurement condition
Ambient temperature: Input power level: Terminating impedance: * Input: Output: 23 0 C dBm
Filter specification
TFS 900
1/5
142 || -4,5 pF 197 || -3,7 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 900 is the minimum of the pass band attenuation. This value is defined as the insertion loss ae. The nominal frequency fN is fixed at 900 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss (reference level) Nominal frequency Passband Pass band ripple Relative attenuation 1 MHz ... 740 MHz ... 1040 MHz ... 1060 MHz ... Group delay ripple in PB Input power level Operating temperature range Storage temperature range Temperature coefficient of frequency TCf ** OTR 740 760 1060 2000 arel MHz MHz MHz MHz
ae = amin
typ. value
15,2 140,5 0,4 MHz dB dB
tolerance / limit
max. 17,0 900,0 min. max. fN 60 1,0 dB MHz MHz dB
fN PB
44 43 39 42 3,5
dB dB dB dB ns
min. min. min. min. max.
30 25 25 30 10
dB dB dB dB dBm
-96 ppm/k
- 10 C ... + 70C - 45 C ... + 85C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team. **) fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 900.doc
Version 1.1
18.05.2006
VI TELEFILTER
Filter characteristic
0
Filter specification
TFS 900
2/5
0
0.117
-8
-1
0.114
-16
-2
0.111
-24
-3
0.108
magnitude in dB
magnitude in dB
-32
-4
0.105 delay in s
-40
-5
0.102
-48
-6
0.099
-56
-7
0.096
-64
-8
0.093
-72
-9
0.09
-80 300
420
540
660
780
900 1020 frequency in MHz
1140
1260
1380
1500
-10 814
831.2
848.4
865.6
882.8 900 917.2 frequency in MHz
934.4
951.6
968.8
0.087 986
Construction and pin connection
(All dimensions in mm)
7 5
900 U20
1 3
1 2 3 4 5 6 7 8
Date code
Ground Input RF Return Input Ground Ground Output RF Return Output Ground
2,54
1
3
1,2 Max.
SQ 3,81 +0,2/-0,1
Date code: U V W ...
Year + week 2006 2007 2008
d
12 0% %
7
1,78
5
50 Ohm Test circuit
0,1
1,78
0,6
L1
3 2
7
L2
SAW
6
C2
C1
1, 4, 5, 8
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 900.doc
Version 1.1
18.05.2006
VI TELEFILTER
Stability characteristics
Filter specification
TFS 900
3/5
After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Change of temperature: 4. Resistance to solder heat (reflow): 500g, 1 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5 g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 -55 C to 125C / 30 min. each / 10 cycles DIN IEC 68 part 2 - 14 Test N reflow possible: twice max.; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4;
This filter is RoHS compliant (2002/95/EG, 2005/618/EG)
Packing
Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: reel of empty components at start: reel of empty components at start including leader: trailer:
Pull Off Direction
3000 min. 300 mm min. 500 mm min. 300 mm
Tape (all dimensions in mm) W : 12,00 0,3 Po : 4,00 0,1 Do : 1,50 +0,1/-0 E : 1,75 0,1 F : 5,50 0,05 G(min) : 0,75 P2 : 2,00 0,05 P1 : 8,00 0,1 D1(min) : 1,50 Ao : 4,30 0,1 Bo : 4,30 0,1 Ct : 9,5 0,1
P1 t Do PIN Marker Po P2
E G Ct Bo F
Ko
Date Code
Typ
D1
Ao
W2
Reel (all dimensions in mm) A : 330 W1 : 12,4 +2/-0 W2(max) : 18,4 N(min) : 50 C : 13,0 +0,5/-0,2
C A N
W1
The minimum bending radius is 45 mm.
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
G
W
Filename: tfs 900.doc
Version 1.1
18.05.2006
VI TELEFILTER
Air reflow temperature conditions
Filter specification
TFS 900
4/5
Conditions Average ramp-up rate (30C to 217C) > 100C > 150C > 217C Peak temperature Time within 5C of actual peak temperature Cool-down rate (Peak to 50C) Time from 30C to Peak temperature
Exposure less than 3C/second between 300 and 600 seconds between 240 and 500 seconds between 30 and 150 seconds max. 260C between 10 and 30 seconds less than 6C/second no greater than 300 seconds
Chip-mount air reflow profile Temperature / C
max. 260C
217C
max. 300 s
10 ... 30 s 30 ... 150 s
Time / s
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Filename: tfs 900.doc
Version 1.1
18.05.2006
VI TELEFILTER
History Version
1.0 1.1
Filter specification
TFS 900
5/5
Reason of Changes
- Generation of development specification - generated filter specification - added terminating impedances - added typical values - added filter characteristic - added test circuit
Name Chilla Chilla
Date 13.12.2005 18.05.2006
Tele Filter GmbH Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.


▲Up To Search▲   

 
Price & Availability of TFS900

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X