|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Specification AXIS60-11 Oscillator type : VCXO Parameter Frequency range Standard frequencies Frequency stability Initial tolerance vs. temperature in operating frequency range 0~+70C (steady state) vs. supply voltage variation vs. load change long term (aging) per year Frequency adjustment range Mechanical (internal trimmer) Electronic Frequency Control (EFC) range EFC voltage VC EFC slope (f / VC) EFC linearity EFC input impedance RF output Signal waveform Load RL Level Harmonics attenuation Anharmonics attenuation Phase Noise L(f) Issue: 03 Date: 2005-07-15 min. typ. 64,250 max. Unit MHz MHz ppm ppm ppm Condition Other frequencies on request @+25C 0~+70C -10 -20 10 20 -3 -1 -2 3 1 2 ppm VS 5 % ppm RL 5 % ppm/year @ 40C ppm ppm N.A. 100 0 positive 10 1 SINUS 50 0 5,0 V % k dBm dBc dBc dBc dBc dBc dBc V mA C C mm gram V IEC 60286-3 HBM as in IEC 610004-2 -2 -20 -40 +2 Supply voltage VS Current consumption (steady state) Enable/disable function Operable temperature range Storage temperature range Enclosure (see drawing) Weight Packing ESD Sensitivity 4.75 -95 -115 -125 -125 5.0 @ 100 Hz @ 1 kHz @ 10 kHz @ 100 kHz @ +25C 5.25 45 -40 +85 -40 +85 19.1x13.1x5.5 max 3 Tape & reel 1500 IEC 61837 CO20 modified Notes: 1. Terminology and test conditions are according to IEC standard IEC60679-1, unless otherwise stated Ordering Code: Model (Specification) AXIS60-11 Frequency [MHz] 64,250 GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany AXIS60-11 page 1(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com Enclosure drawing Pin connections Pin # Symbol 1 VC 2 GND 4 RF OUT 5 VS Function Control Voltage (EFC) Ground RF Output Supply Voltage Environmental conditions Test Visual inspection, dimensions Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* Bump* Free fall* IEC 60068 Part ... IEC 60679-1 clause ... 4.3 4.6.2 4.6.3 Test conditions Enclosure styles as in IEC 60679-3 or 61837, if applicable Gross leak: Test Qc, Fine leak: Test Qk Test Ta (235 5)C Method 1 Test Tb Method 1A, 5s Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Eb, 4000 bumps per Axes, 40g, 6 ms Test Ed procedure 1, 2 drops from 1m height Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Na, 10 cycles at extremes of operating temperature range Test Ba, 16 h at upper temperature indicated by climatic category Test Db variant 1 severity b), 55C/95% r.H., 6 cycles Test Aa, 2 h at lower temperature indicated by climatic category Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16, 4.6.15 (5 cycles) Test Ca, 56 days 2-17 2-20 2-58 2-27 2-29 2-32 4.6.8 4.6.6 4.6.9 4.6.7 Vibration, sinusoidal* 2-6 Rapid change of temperature Dry heat Damp heat, cyclic* Cold Climatic sequence* Damp heat, steady state* Endurance tests - ageing - extended aging 2-14 2-2 2-30 2-1 1-7 2-3 4.6.5 4.6.14 4.6.15 4.6.16 4.6.17 4.6.18 4.7.1 4.7.2 30 days @ 85C, OCXO @25C 1000h, 2000h, 8000h @85C GmbH & Co. KG Wasemweg 8 D-74821 Mosbach Germany AXIS60-11 page 2(2) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: info@axtal.com |
Price & Availability of AXIS60-11 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |