![]() |
|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS398B.doc version 1.0 10.05.2001 VI TELEFILTER Measurement condition Ambient temperature TA: Input power level: Terminating impedances at fc: 23 C 0 dBm input: output: Filter Specification TFS 398B 1/5 t.b.d. t.b.d. Characteristics Remark: Reference level for the relative attenuation arel of the TFS 398B is the minimum of the pass band attenuation aminIt is defined as the insertion loss ae. The centre frequence fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 398 MHz without tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc. Data Insertion loss (Reference level) Nominal frequency Centre frequency 1 dB Passband width Relative attenuation fN fN 13,5 MHz fN - 298 fN - 88 fN - 33 fN + 72 Phase linearity Operating temperature range Temperature coefficient of frequency ( Tcf ) ***) Frequency inversion temperature To Input power level: *) at room temperature typ. value ae 398,0 MHz tolerance / limit max. 12,0 398,0 dB MHz *) fN fc min. 15,0 arel fN 13,5 MHz fN 15 MHz fN - 88 fN - 58 fN - 30 fN 602 MHz MHz MHz MHz max. max. min. min. min. min. max. 0,7 1,0 40 45 50 40 4,0 MHz dB dB dB dB dB dB p-p MHz MHz MHz MHz - 30 C ... + 70 C 94 ppm/ K t.b.d max. 10,0 dBm Generated: Checked/Approved: VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS398B.doc version 1.0 10.05.2001 VI TELEFILTER Construction and pin connection (All dimensions in mm) 13.3 Max 13.3 Filter Specification TFS 398B 2/5 10 11 12 9 8 7 6 6.5 MAX. TFS 398 B N19 1 2 3 4 Datecode 5 10 1 2 3 4 5 6 7 8 9 10 11 12 Ground Ground Ground Ground Output Output RF Return Ground Ground Ground Ground Input Input RF Return Date code: Year+week L 1999 M 2000 N 2001 ...... 50 matching network: t.b.d. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS398B.doc version 1.0 10.05.2001 VI TELEFILTER Stability characteristics Filter Specification TFS 398B 3/5 After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Reel of empty components at start: Reel of empty components at start including leader: Trailer Tape (all dimensions in mm) W Po Do E : : : : 24 0,3 4 0,1 1,5 + 0,1 1,75 0,1 11,5 0,1 0,60 2 12 1,5 7,1 13,9 0,1 0,1 0,2 0,2 COVER TAPE 1700 min 300 mm min 500 mm min 300 mm EMBOSSED CARRIER TAPE Do Po P2 E Ao F W F : G (min) : P2 : P1 : D1(min) : Ao Bo CT : : : D1 CT Bo G P1 21,5 0,1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,40 +2,0 30,4 60 C A 13 0,5/-0.2 N W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the left side of the tape. VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS398B.doc version 1.0 10.05.2001 VI TELEFILTER Filter Specification TFS 398B 4/5 Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information TFS398B.doc version 1.0 10.05.2001 VI TELEFILTER History Version 1.0 Reason of Changes Filter Specification TFS 398B 5/5 Name Steiner Date 10.05.2001 - generation of specification according to customer specification EED/N/WR VI TELEFILTER Potsdamer Strae 18 D 14 513 TELTOW / Germany Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 E-Mail: tft@telefilter.com Vectron International, Inc. 267 Lowell Road Hudson, NH 03051 / USA Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information |
Price & Availability of TFS398B
![]() |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |