|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
TFS119A.doc version 1.6 14.09.2000 ______________________________________________________________________________________________________ VI TELEFILTER SAW Filter Specification TFS 119A 1/5 ______________________________________________________________________________________________________ Measurement condition Ambient temperature: 23 C Input power level: 0 dBm Terminating impedances for input: 750 Ohm // -3.9 pF for output: 750 Ohm // -3.9 pF External coil: 279 nH Characteristics Remark: Reference level for the relative attenuation arel of the TFS 119A is the insertion loss. The insertion loss ae is defined as the insertion loss at the nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 119.6 MHz without tolerance. The specified values have to be reached in operating temperature range. Data Insertion loss (Reference level) Nominal frequency Centre frequency 1 dB bandwidth fN fC typ. Value ae 1.85 dB tolerance/limit 1.25...3.25 dB 119,605 MHz BW 162 45 43...48 27...89 1,5 : 1 GD 4,2 s max. max. MHz dB dB dB min. min. min. max. 119,600 MHz 20 30 10 1,8 : 1 8,2 13 s dBm dB dB dB Relative attenuation arel fN 0,8 MHz ... fN 1,8 MHz MHz fN 1,8 MHz ... fN 6 fN 6 MHz ... fN 100 MHz VSWR @ fN Group delay @ fN Input power Operating temperature range Temperature coefficient of frequency Frequency inversion temperature TC - 5 C ... + 80 C ca. - 0,036 + 35 C ppm/K Generated: Checked / approved: VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS119A.doc version 1.6 14.09.2000 ______________________________________________________________________________________________________ VI TELEFILTER SAW Filter Specification TFS 119A 2/5 ______________________________________________________________________________________________________ Construction, pin configuration and 50 - matching network (All dimensions in mm) TFS 119 A M37 DateCode Datecode: K L M ... Year+week 1998 1999 2000 Pin 1, 2, 3, 6, 7, 8, 10: Pin 4: Pin 5: Pin 9: Ground Output External Coil Input 50 Ohm Test circuit 1 50 Ohm L1 9 4 L2 50 Ohm C1 SAW 5 1,2,3,6,7,8,10 L3 C2 50 Ohm Test circuit 2 50 Ohm C1 9 4 C2 50 Ohm L1 SAW 5 L3 L2 1,2,3,6,7,8,10 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS119A.doc version 1.6 14.09.2000 ______________________________________________________________________________________________________ VI TELEFILTER SAW Filter Specification TFS 119A 3/5 ______________________________________________________________________________________________________ Stability Characteristics After the following tests the filter shall meet the whole specification: 1. Shock: 2. Vibration: 3. Damp heat: (cycle) 4. Resistance to solder heat (reflow): 500g, 18 ms, half sine wave, 3 shocks each plane; DIN IEC 68 T2 - 27 10 Hz to 500 Hz, 0,35 mm or 5g respectively, 1 octave per min, 10 cycles per plan, 3 plans; DIN IEC 68 T2 - 6 25 C to 55C / 95% r.H. / 10 cycles DIN IEC 68 - 2 - 30 Db max. 2 times reflow process; for temperature conditions refer to the attached "Air reflow temperature conditions" on page 4; Packing Tape & Reel: IEC 286 - 3, with exception of value for N and minimum bending radius; tape type II, embossed carrier tape with top cover tape on the upper side; max. pieces of filters per reel: Real of empty components at start: Real of empty components at start including leader: Trailer 3000 min 300 mm min 500 mm min 300 mm Tape (all dimensions in mm) W Po Do : : : 24 4 0,3 0,1 EMBOSSED CARRIER TAPE Do Po P2 1,5 + 0,1 1,75 0,1 7,5 0,1 0,6 2 8 1,5 5,6 11,8 21,5 0,1 0,1 G E Ao F W E : F : G (min) : P2 : P1 : D1(min) : Ao : Bo CT : : D1 CT Bo 0,1 0,1 0,1 COVER TAPE P1 W2 Reel (all dimensions in mm): A W1 W2 (max) : N (min) C : : : : 330 24,4 +2 30,4 60 C A N 13 +0,5/-0,2 W1 The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape. The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on the right side of the tape. VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. TFS119A.doc version 1.6 14.09.2000 ______________________________________________________________________________________________________ VI TELEFILTER SAW Filter Specification TFS 119A 4/5 ______________________________________________________________________________________________________ Air reflow temperature conditions 1st and 2nd air reflow profile Name: Temperature: Time: pre-heating periods 150 C - 170 C 60 sec. - 90 sec. main-heating periods over 200 C 20 sec. - 25 sec. peak temperature 255 C 5 C Chip-mount air reflow profile 260 240 220 200 180 temperature / C 160 140 120 100 80 60 40 20 0 0 20 40 60 80 100 120 time / sec. 140 160 180 200 220 240 Table for temperature vs. time during the air reflow process Tolerance of temperatures: 5 C time / sec. 0 10 20 30 40 50 60 70 80 90 100 110 120 130 temperature / C 23 34 46 60 80 103 121 134 143 150 154 156 158 159 time / sec. 140 150 160 170 180 190 195 200 205 210 215 220 230 240 temperature / C 160 161 164 170 180 205 230 255 230 205 180 165 140 120 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. version 1.6 14.09.2000 ______________________________________________________________________________________________________ TFS119A.doc VI TELEFILTER SAW Filter Specification TFS 119A 5/5 ______________________________________________________________________________________________________ History Version 1.2 Reason of Changes Add preliminary values for termination impedance Add history Modify monthly date code into weekly date code Corrected tape and reel information Add final termination conditions Add typical filter data Add limits for insertion loss Add maximum input power Add reletive attenuation value for FN 6 MHz ... FN 100 MHz Add group delay Notice 1 dB bandwidth instead of 3 dB bandwidth Increase window for insertion loss to two dB Change filter name to TFS119A Add external coil Change input power level to 13 dBm Remove typical filter values Remove termination impedances Add termination impedances and coupling coil value Define insertion loss window Add typical values for filter data Add maximum value for group delay Correct filter marking Name Dr. Wall Date 09.05.2000 1.3 Dr. Wall 16.06.2000 1.4 Dr. Wall 28.06.2000 1.5 Dr. Wall 19.07.2000 1.6 Dr. Wall 14.09.2000 VI TELEFILTER Vectron International, Inc. Potsdamer Strae 18 267 Lowell Road D 14 513 TELTOW / Germany Hudson, NH 03051 / USA Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30 Tel: (603) 598-0070 Fax: (603) 598-0075 E-Mail: tft@telefilter.com E-Mail: vti@vtinh.com VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information. |
Price & Availability of TFS119A | |
|
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |