Part Number Hot Search : 
TA1152A 1012214 78IUP LVC1G0 SBL2045 TEVAL C8800 FST8280L
Product Description
Full Text Search
 

To Download HY7-P Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Current Transducer HY7-P
For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
IPN
= 7.5 A
Electrical data
Primary nominal r.m.s. current IPN (A) 7.5 Primary current measuring range IP (A) 22.5 Primary conductor (mm) Type
1.0
HY 7-P
Features
V mA kV V M V k
VC IC IP Vd Vb R IS VOUT ROUT RL
Supply voltage ( 5 %) Current consumption Overload capability (1 ms) R.m.s. voltage for AC isolation test, 50/60Hz, 1 min R.m.s. rated voltage, safe separation Isolation resistance @ 500 VDC Output voltage @ IPN, RL = 10 k, TA = 25C Output internal resistance Load resistance
15 10 50 x IPN 2.5 500 1) > 1000 4 100 >1
* Hall effect measuring principle * Galvanic isolation between primary * Isolation voltage 2500 V~ * Compact design for PCB mounting * Low power consumption * Extended measuring range (3 x IPN) * Insulated plastic case recognized
according to UL 94-V0. and secondary circuit
Accuracy - Dynamic performance data
Advantages
<1 % < 1 % of IPN < 40 mV < 15 mV 1.5 mV/K 3 mV/K < 0.1 %/K <3 s > 50 A/s DC .. 50 kHz
X
L
VOE VOH V OT TC TCG tr di/dt f
Accuracy @ IPN, TA = 25C (without offset) Linearity 2) (0 .. IPN) Electrical offset voltage, TA = 25C Hysteresis offset voltage @ I P = 0; after an excursion of 1 x IPN Thermal drift of VOE Thermal drift of the gain (% of reading) Response time @ 90% of I P di/dt accurately followed Frequency bandwidth 3) (- 3 dB)
* Easy mounting * Small size and space savings * Only one design for wide current * High immunity against external
interference ratings range
typ. max.
Applications
* General purpose inverters * Switched-Mode Power Supplies * AC motor speed control * Battery supplied applications * Uninterruptible Power Supplies * Power supplies for welding
applications. (UPS) (SMPS)
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards 4) - 10 .. + 80 - 25 .. + 85 < 14 EN 50178 C C g
Notes :
1) 2) 3)
4)
Pollution class 2, overvoltage category III Linearity data exclude the electrical offset. Please refer to derating curves in the technical file to avoid excessive core heating at high frequency Please consult characterisation report for more technical details and application advice. 981007/3
LEM Components
Tope Co., Ltd. Tel: (02) 8228-0658 Fax: (02) 8228-0659 http://www.sensor.com.tw
www.lem.com e-mail: tope@ms1.hinet.net
HY 7-P D im e ns io ns
(in m m ) 36 .0 M ax . 32 .0 M ax .
JA PA N
18 .0 12 .0
12 M ax .
HY 7- P 974 8
3 .00 .5 3 x 2 .54
(0 .5)
( 1.0) 8 .50 .3
(0 .3) 1.4 0 .3 3 .90 .3
18 .5 0 .3
1234
5
6
PC B M O UNT ING DIM ENS IO NS HY 7-P
(in m m 0 .1, ho le -0 , +0 .2)
ho les d ia 2 4 ho les d ia 1
PIN A RRA NG EM ENT 1 +15V 2 15V 3 OUTPUT 4 0V 5 PRIMARY IN 6 PRIMARY OUT
3 x 2 .54
10
8 .5
LEM reserves the right to change limits and dimensions.